How to cite item

Using M-mode ultrasonography to assess diaphragm dysfunction and predict the success of mechanical ventilation weaning in elderly patients

  
@article{JTD15549,
	author = {Daozheng Huang and Huan Ma and Wenzhao Zhong and Xiaoting Wang and Yan Wu and Tiehe Qin and Shouhong Wang and Ning Tan},
	title = {Using M-mode ultrasonography to assess diaphragm dysfunction and predict the success of mechanical ventilation weaning in elderly patients},
	journal = {Journal of Thoracic Disease},
	volume = {9},
	number = {9},
	year = {2017},
	keywords = {},
	abstract = {Background: Ultrasonography (US) is a non-invasive and commonly available bedside diagnostic tool. The aim of this study was to assess the utility of M-mode US on ventilator weaning outcomes in elderly patients. 
Methods: This was a single center, prospective, observational study in patients aged 80 years or older who were in the medical intensive care unit, had undergone mechanical ventilation for >48 hours, and met the criteria for a spontaneous breathing trial (SBT). For 30 minutes at the start of SBT, each hemi-diaphragmatic movement and the velocity of contraction were evaluated by M-mode US. The the area under the receiver operating characteristic curve (AUROC) was calculated to determine the ability for measured variables to predict successful ventilator weaning.
Results: Forty patients were enrolled and assessed, grouped by those who had US-diagnosed diaphragm dysfunction (DD; 30/40; 75%) and those who did not (10/40; 25%). Patients with DD had a significantly longer total mechanical ventilation duration (536.4±377.05 vs. 250±109.02 hours, P=0.02) and weaning time (425.9±268.31 vs. 216.0±134.22 hours, P=0.002) than patients without DD. Patients with DD also had a higher incidence of weaning failure than patients without DD (24/30 vs. 4/10, P=0.017). Analysis of the receiver operating characteristic (ROC) curve (ROC) curve showed that the optimal cut-off values to predict weaning success were >10.7 mm for the right diaphragmatic movement, and >21.32 mm/s for the right diaphragmatic velocity of contraction; AUROC were 0.839 (95% CI, 0.689–0.936) and 0.833 (95% CI, 0.682–0.932), respectively. The sensitivity, specificity, positive and negative likelihood ratios for predicting weaning success were 83.33% vs. 66.67%, 75.00% vs. 92.86%, 3.33 vs. 9.33, and 0.22 vs. 0.36, for right diaphragmatic movement and diaphragmatic contraction velocity, respectively. 
Conclusions: When assessed by M-mode US, DD appeared to be common in ventilated patients aged 80 years or older and was associated with a higher incidence of weaning failure. Larger right diaphragmatic movements or faster right diaphragmatic contraction velocity appeared to be good predictors of mechanical ventilation weaning success in elderly patients.},
	issn = {2077-6624},	url = {https://jtd.amegroups.org/article/view/15549}
}