@article{JTD28554,
author = {Fei Liu and Wei Zhang and Guili Wang and Tong Yuan and Xiaolong Shu and Daqiao Guo and Lixin Wang and Weiguo Fu},
title = {Long-term outcomes of balloon-expandable bare stent as chimney stent in thoracic endovascular aortic repair for supra-aortic branches reconstruction},
journal = {Journal of Thoracic Disease},
volume = {11},
number = {4},
year = {2019},
keywords = {},
abstract = {Background: To report the long-term outcomes of balloon-expandable bare stent (BEBS) as chimney stent (CS) in thoracic endovascular aortic repair (TEVAR) for supra-aortic branches reconstruction.
Methods: A total of 33 patients with thoracic aortic diseases underwent TEVAR using BEBSs as CSs for supra-aortic branches reconstruction in our center from 2010 to 2015. The demographics and procedural details were prospectively collected and retrospectively reviewed. All patients were followed up at 1, 3, 6 months and every 1 year thereafter. Postoperative complications and long-term outcomes were recorded.
Results: The technical success rate was 100%. A total of 36 BEBSs were utilized as CSs to reconstruct the supra-aortic branches during TEVAR. The rate of immediate endoleak was 42.4% (14/33), including 12 (36.4%) type Ia endoleaks and 2 (6.1%) type II endoleaks. Two of type Ia endoleaks were managed by balloon dilation and disappeared, while the rest were left with close follow-up. Two type II endoleaks were embolized by coils and excluded by a plug, respectively. One patient (3.0%) died 2 days after the procedure due to the acute rupture of aortic dissection. The mean follow-up time was 61.8 (ranged from 12 to 102) months. The unmanaged 10 type Ia endoleaks were closely observed during the follow-up, of which 7 disappeared at 1 year and 1 disappeared at 2 years. The rest 2 type Ia endoleaks existed without further dilation of the aorta. One patient (3.0%) was re-intervened for the increased false lumen due to the distal residual tears. The long-term mortality was 9.1% (3/33). All CSs kept patent till the end of follow-up. No other complications were found.
Conclusions: The balloon-expandable stent (BES) is a feasible choice as CS for supra-aortic branches reconstruction with long-term patency during TEVAR. However, BEBS may be related to a higher rate of early endoleak.},
issn = {2077-6624}, url = {https://jtd.amegroups.org/article/view/28554}
}