@article{JTD8654,
author = {Maria Teresa Ramieri and Ferdinando Marandino and Paolo Visca and Tommaso Salvitti and Enzo Gallo and Beatrice Casini and Francesca Romana Giordano and Claudia Frigieri and Mauro Caterino and Sandro Carlini and Massimo Rinaldi and Anna Ceribelli and Annarita Pennetti and Pier Luigi Alò and Mirella Marino and Edoardo Pescarmona and Massimo Filippetti},
title = {Usefulness of conventional transbronchial needle aspiration in the diagnosis, staging and molecular characterization of pulmonary neoplasias by thin-prep based cytology: experience of a single oncological institute},
journal = {Journal of Thoracic Disease},
volume = {8},
number = {8},
year = {2016},
keywords = {},
abstract = {Background: Conventional transbronchial needle aspiration (c-TBNA) contributed to improve the bronchoscopic examination, allowing to sample lesions located even outside the tracheo-bronchial tree and in the hilo-mediastinal district, both for diagnostic and staging purposes.
Methods: We have evaluated the sensitivity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) of the c-TBNA performed during the 2005–2015 period for suspicious lung neoplasia and/or hilar and mediastinal lymphadenopathy at the Thoracic endoscopy of the Thoracic Surgery Department of the Regina Elena National Cancer Institute, Rome. Data from 273 consecutive patients (205 males and 68 females) were analyzed.
Results: Among 158 (58%) adequate specimens, 112 (41%) were neoplastic or contained atypical cells, 46 (17%) were negative or not diagnostic. We considered in the analysis first the overall period; then we compared the findings of the first [2005–2011] and second period [2012–2015] and, finally, only those of adequate specimens. During the overall period, sensibility and accuracy values were respectively of 53% and 63%, in the first period they reached 41% and 53% respectively; in the second period sensibility and accuracy reached 60% and 68%. Considering only the adequate specimens, sensibility and accuracy during the overall period were respectively of 80% and 82%; the values obtained for the first period were 68% and 72%. Finally, in the second period, sensibility reached 86% and accuracy 89%. Carcinoma-subtyping was possible in 112 cases, adenocarcinomas being diagnosed in 50 cases; further, in 30 cases molecular predictive data could be obtained.
Conclusions: The c-TBNA proved to be an efficient method for the diagnosis/staging of lung neoplasms and for the diagnosis of mediastinal lymphadenopathy. Endoscopist’s skill and technical development, associated to thin-prep cytology and to a rapid on site examination (ROSE), were able to provide by c-TBNA a high diagnostic yield and molecular predictive data in advanced lung carcinomas.},
issn = {2077-6624}, url = {https://jtd.amegroups.org/article/view/8654}
}