Cone beam computed tomography—the need for future guidance
Editorial

Cone beam computed tomography—the need for future guidance

Jimmy T. Efird1,2, Charulata Jindal3, Tarun K. Podder1,4, Kylie H. Kang5, Tithi Biswas1,4

1Department of Radiation Oncology, Case Western Reserve University School of Medicine, Cleveland, OH, USA; 2VA Cooperative Studies Program Coordinating Center, Boston, MA, USA; 3Harvard Medical School, Harvard University, Boston, MA, USA; 4Department of Radiation Oncology, Case Comprehensive Cancer Center, University Hospitals Cleveland Medical Center, Cleveland, OH, USA; 5Department of Radiation Oncology, Washington University School of Medicine and Alvin J. Siteman Comprehensive Cancer Center, St. Louis, MO, USA

Correspondence to: Dr. Jimmy T. Efird. Department of Radiation Oncology, Case Western Reserve University School of Medicine, Cleveland, OH 44106, USA. Email: jte38@case.edu; jimmy.efird@stanfordalumni.org.

Comment on: Saito Y, Watanabe T, Kanamoto Y, et al. A pilot study of intraoperative localization of peripheral small pulmonary tumors by cone-beam computed tomography: sandwich marking technique. J Thorac Dis 2022;14:2845-54.


Submitted Jul 20, 2022. Accepted for publication Aug 12, 2022.

doi: 10.21037/jtd-22-1008


Cone beam computed tomography (CBCT) represents an important radiologic advancement for generating volumetric images through a process of tomographic reconstruction (1,2). Increasingly, this technique is being used in on-line image guidance during radiation treatment delivery, and for diagnosis and treatment in interventional radiology (3,4).

In contrast to traditional CT scans, which uses a fan-shaped, anode X-ray beam, CBCT employees a round or rectangular cone-shaped beam with an area detector (versus a linear group of detectors) (5). The cone-beam method has relatively short scan times (~1 min) yet yields high quality images with sub-millimeter resolution and high dimensional accuracy (i.e., 3D volumetric data in axial, sagittal, and coronal planes). While radiation emanating from a standard CBCT is considerably lower (on the order of 10-fold less) than conventional CT scans, the levels are not inconsequential and well-exceed daily background amounts of radiation in the natural environment (~8.2 µSv per day in the United States) (5,6). Furthermore, some CBCT scanners use intensified X-ray sources that output substantially higher levels of radiation. Accordingly, clinicians and technical staff should err on the side of caution when routinely performing CBCT scans.

This minimally invasive imaging technique provides several benefits, including guidance for radiation therapy and as an important alternative to open surgery and biopsy in many applications. When administering radiation therapy, a key challenge is identifying disease volume while avoiding nearby normal tissue (7). Owing to the relatively short acquisition time of CBCT, this imaging modality is ideal for efficiently monitoring ongoing tumor volume changes over the course of treatment and is routinely used during radiation treatment delivery. The use CBCT in such settings is even more important for a highly mobile target like lung cancer to make radiation treatment delivery more accurate. The use of CBCT has shown promise as a prognostic tool for assessing gradual tumor regression and consequently better outcomes for patents presenting with locally advanced, unresectable non-small cell lung cancer and undergoing definitive chemoradiation (7-10). Nonetheless, the prognostic value needs to be further explored in future studies.

In a recent preliminary study of small pulmonary nodule localization, CBCT and augmented fluoroscopy was successfully used to interactively guide lung resection during video-assisted thoracic surgery (11). The outcome of this study highlights the potential of CBCT as a non-invasive method to improve the perception of targeted small tumors. In past practice, precisely locating these lesions represented a significant surgical challenge, often requiring an invasive preoperative procedure under CT-fluoroscopic guidance involving metal hook-wire placement and coils.

The current study by Saito and colleagues (12) further improved on the intraoperative localization of small peripheral pulmonary tumors by using a sandwich marking technique in combination with CBCT. In this pilot investigation, metal clips were placed in several places of visceral pleura, where the target lesion was sandwiched by marking clips. The detection rate of this arrangement was 100% effective, without any marking-related complication. Furthermore, radiation exposure to skin with CBCT was comparable to that with multidetector computed tomography and less than that of the Lipiodol marking method if the number of CBCT scans was less than four (but higher for four or more scans).

Radiation exposure is cumulative. According to the linear no-threshold model used by the US Environmental Protection Agency, there is no safe dose of ionizing radiation (13). Controversy exists regarding whether or not the radiation dose attributable to CBCT scans, although seemingly inconsequential, poses an immediate or long-term health risk. While efforts to decrease scattered radiation (generated by the interaction of the main radiation beam with the jaws and collimators, airborne particles, objects in the treatment field, and the patient during transit from the focal spot to detector) and reduce scan times have been suggested, the practical aspects of such recommendations remain challenging (14). A certain level of radiation is needed within the field of view to maintain image quality and accordingly, there are functional limits on lowering scattered radiation by adjusting the radiation output (15). To date, no standardized guidance exists for reducing scattered radiation dose for CBCT imaging (15).

Radiation safety implies keeping the dose “as low as reasonably achievable (ALARA)” by adhering to the three basic protective measures of “time, distance, and shielding” (16,17). A prudent strategy is to minimize radiation dosing to a patient when feasible, even if the radiation dose for CBCT is relatively low in comparison with therapeutic doses. Shielding alone decreases the absorption of non-scattered radiation by up to 95% (17). As suggested in the Saito manuscript, more clinical experience could facilitate the identification of target lesions with fewer scans, and thereby reduce the radiation exposure of patients (12). The authors also recommend additional research to compare radiation exposure among the different marking methods for CBCT.


Acknowledgments

Funding: None.


Footnote

Provenance and Peer Review: This article was commissioned by the editorial office, Journal of Thoracic Disease. The article did not undergo external peer review.

Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://jtd.amegroups.com/article/view/10.21037/jtd-22-1008/coif). The authors have no conflicts of interest to declare.

Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved.

Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.


References

  1. Gingold E. Modern Fluoroscopy Imaging Systems. Philadelphia, PA: 2022. Available online: https://www.imagewisely.org/Imaging-Modalities/Fluoroscopy/Modern-Imaging-Systems
  2. Schueler BA. The AAPM/RSNA physics tutorial for residents: general overview of fluoroscopic imaging. Radiographics 2000;20:1115-26. [Crossref] [PubMed]
  3. Oldham M, Létourneau D, Watt L, et al. Cone-beam-CT guided radiation therapy: A model for on-line application. Radiother Oncol 2005;75:271-8. [Crossref] [PubMed]
  4. Thwaites DI, Tuohy JB. Back to the future: the history and development of the clinical linear accelerator. Phys Med Biol 2006;51:R343-62. [Crossref] [PubMed]
  5. Kumar M, Shanavas M, Sidappa A, et al. Cone beam computed tomography - know its secrets. J Int Oral Health 2015;7:64-8. [PubMed]
  6. National Council on Radiation Protection and Measurements. Radiation protection in dentistry: Recommendations of the National Council on Radiation Protection and Measurements Bethesda, MD; 2003. Contract No.: Report No. 145. Available online: https://www.aapm.org/pubs/ncrp/detail.asp?docid=33
  7. Kang KH, Efird JT, Podder TK, et al. A Pilot Study Examining the Prognostic Utility of Tumor Shrinkage on Cone-Beam Computed Tomography (CBCT) for Stage III Locally Advanced Non-Small Cell Lung Cancer Patients Treated with Definitive Chemoradiation. Int J Environ Res Public Health 2021;18:3241. [Crossref] [PubMed]
  8. Jabbour SK, Kim S, Haider SA, et al. Reduction in Tumor Volume by Cone Beam Computed Tomography Predicts Overall Survival in Non-Small Cell Lung Cancer Treated With Chemoradiation Therapy. Int J Radiat Oncol Biol Phys 2015;92:627-33. [Crossref] [PubMed]
  9. Wald P, Mo X, Barney C, et al. Prognostic Value of Primary Tumor Volume Changes on kV-CBCT during Definitive Chemoradiotherapy for Stage III Non-Small Cell Lung Cancer. J Thorac Oncol 2017;12:1779-87. [Crossref] [PubMed]
  10. van Timmeren JE, van Elmpt W, Leijenaar RTH, et al. Longitudinal radiomics of cone-beam CT images from non-small cell lung cancer patients: Evaluation of the added prognostic value for overall survival and locoregional recurrence. Radiother Oncol 2019;136:78-85. [Crossref] [PubMed]
  11. Rouzé S, de Latour B, Flécher E, et al. Small pulmonary nodule localization with cone beam computed tomography during video-assisted thoracic surgery: a feasibility study. Interact Cardiovasc Thorac Surg 2016;22:705-11. [Crossref] [PubMed]
  12. Saito Y, Watanabe T, Kanamoto Y, et al. A pilot study of intraoperative localization of peripheral small pulmonary tumors by cone-beam computed tomography: sandwich marking technique. J Thorac Dis 2022;14:2845-54. [Crossref] [PubMed]
  13. Cardarelli JJ 2nd, Ulsh BA. It Is Time to Move Beyond the Linear No-Threshold Theory for Low-Dose Radiation Protection. Dose Response 2018;16:1559325818779651. [Crossref] [PubMed]
  14. Paul J, Chacko A, Mbalisike EC, et al. Cone-beam computed tomography imaging: therapeutic staff dose during chemoembolisation procedure. J Radiol Prot 2014;34:843-51. [Crossref] [PubMed]
  15. Lee CH, Ryu JH, Lee YH, et al. Reduction of radiation exposure by lead curtain shielding in dedicated extremity cone beam CT. Br J Radiol 2015;88:20140866. [Crossref] [PubMed]
  16. ALARA – As Low As Reasonably Achievable: Centers for Disease Control and Prevention; 2022 [updated May 17, 2022. Available online: https://www.cdc.gov/nceh/radiation/alara.html#:~:text=The%20guiding%20principle%20of%20radiation,if%20the%20dose%20is%20small
  17. Matikka H, Virén T. Radiation dose reduction in cone-beam computed tomography of extremities: evaluation of a novel radiation shield. J Radiol Prot 2014;34:N57-63.
Cite this article as: Efird JT, Jindal C, Podder TK, Kang KH, Biswas T. Cone beam computed tomography—the need for future guidance. J Thorac Dis 2022;14(10):3681-3683. doi: 10.21037/jtd-22-1008

Download Citation