Factors influencing continuous positive airway pressure adherence in elderly with obstructive sleep apnea
Original Article of Sleep Section

Factors influencing continuous positive airway pressure adherence in elderly with obstructive sleep apnea

Nantaporn Tiyapun1,2, Kanokkarn Sunkonkit2,3^, Warawut Chaiwong4^, Ratirat Worasuthaneewan2, Theerakorn Theerakittikul2,4^

1Division of Neurology, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 2Sleep Disorders Center, Center of Medical Excellence, Chiang Mai University, Chiang Mai, Thailand; 3Division of Pulmonary and Critical Care, Department of Pediatrics, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand; 4Division of Pulmonary, Critical Care and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand

Contributions: (I) Conception and design: All authors; (II) Administrative support: T Theerakittikul, R Worasuthaneewan; (III) Provision of study materials or patients: T Theerakittikul, K Sunkonkit, R Worasuthaneewan, N Tiyapun; (IV) Collection and assembly of data: T Theerakittikul, R Worasuthaneewan; (V) Data analysis and interpretation: T Theerakittikul, W Chaiwong, R Worasuthaneewan; (VI) Manuscript writing: All authors; (VII) Final approval of manuscript: All authors.

^ORCID: Kanokkarn Sunkonkit, 0000-0003-2725-4636; Warawut Chaiwong, 0000-0003-4459-7681; Theerakorn Theerakittikul, 0000-0001-6182-6218.

Correspondence to: Theerakorn Theerakittikul, MD, FCCP. Division of Pulmonary, Critical Care and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, 110 Inthavaroros Rd., Sriphum, Maung Chiang Mai, Chiang Mai, 50200 Thailand. Email: theerakorn.t@cmu.ac.th.

Background: Continuous positive airway pressure (CPAP) is the most effective treatment for symptomatic obstructive sleep apnea (OSA). The identification of actual predictors of CPAP adherence in real-world practice is essential since it enhances more individualized management for the patient. CPAP acceptance and adherence in elderly patients with OSA have the same challenges but the conclusion remains unclear. Therefore, our aim was to explore the factors influencing the adherence of CPAP in elderly OSA patients.

Methods: The retrospective observational study was conducted from OSA patients’ computerized medical records at Sleep Disorders Center, Center of Medical Excellence, Chiang Mai University Hospital, Chiang Mai, Thailand between 2018 and 2020. Multivariable risk regression analyses were performed to evaluate the independent factors associated with CPAP non-acceptance and CPAP non-adherence.

Results: Of the 1,070 patients who underwent overnight polysomnography (PSG), 336 (31.4%) were elderly. Of 759 patients who accepted CPAP treatment, 221 (29.1%) were elderly, including 27 (12.2%) non-adherences, 139 (62.9%) adherences and 55 (24.8%) loss follow-up. Elderly patients with adverse attitudes toward CPAP use affected adherence to treatment [adjusted risk ratio (RR) =4.59, 95% CI: 1.79, 11.78, P=0.002]. Female was also associated with low CPAP adherence with adjusted RR =3.10 (95% CI: 1.07, 9.01), P=0.037.

Conclusions: In our largest cohort to date, elderly OSA patients treated with CPAP over long-term follow-ups demonstrated that adherence rates were associated with personal life issues and adverse attitudes towards treatment as well as health problems. Female was also associated with low CPAP adherence. Therefore, in the elderly with OSA, the indication and treatment of CPAP should be customized individually, and if prescribed, regular monitoring to address noncompliance and tolerance should be considered.

Keywords: Obstructive sleep apnea; continuous positive airway pressure; acceptance; adherence; elderly


Submitted Jan 03, 2023. Accepted for publication May 06, 2023. Published online May 30, 2023.

doi: 10.21037/jtd-23-8


Highlight box

Key findings

• The adherence of CPAP used in elderly with OAS was associated with personal life issues and adverse attitudes towards treatment as well as health problems.

What is known and what is new?

• Every sleep center tries their best to enhance CPAP adherence by implementing CPAP education strategies.

• Elderly patients with adverse attitudes toward CPAP use and female affected adherence to CPAP treatment.

What is the implication, and what should change now?

• In the elderly with OSA, the indication and treatment of CPAP should be customized individually, and if prescribed, regular monitoring to address noncompliance and tolerance should be considered.


Introduction

Obstructive sleep apnea (OSA) is a disorder characterized by intermittent upper airway obstruction during sleep, recurring oxygen desaturation, and increasing arousals from sleep with blood pressure and heart rate fluctuations (1,2). These repeated episodes lead to various pathophysiological conditions, such as sleep restriction, sleep fragmentation, and intermittent hypoxia resulting in unrefreshing sleep and excessive daytime sleepiness (EDS). Factors associated with increased risk of OSA including male gender, increased body mass index (BMI), snoring, metabolic syndrome, high blood pressure, and increased age (3-5). Moderate to severe OSA, apnea-hypopnea index (AHI) ≥15 events/hour, are associated with a higher risk of cardiovascular morbidity and mortality (6,7). Moreover, untreated OSA has been associated with diabetes mellitus (DM), cardiovascular diseases (1,8,9), neurocognitive impairment (10), and road traffic accidents (11,12).

Continuous positive airway pressure (CPAP) is a very effective treatment for OSA (13,14), and is expressed as the gold standard therapeutic intervention for this disorder, yet patient adherence remains essential to its success. Besides, CPAP treatment has been shown in several trials to have clinical benefits including improvement from both subjective symptoms and life-threatening conditions (15-17). Despite the benefits of CPAP, overall acceptance and adherence rates are not fully optimized with an estimated range reported to be between 46–80% across all age groups (18,19). Additional studies have shown that subjective sleep-related symptoms (20), the severity of OSA (21), knowledge of CPAP’s effectiveness and side effects (22,23), discomfort (24), as well as behavioral and motivational aspects (25-27) are all factors that influence adherence to CPAP therapy. CPAP adherence should be the cornerstone for a successful outcome because it reflects the longer and sustainable benefits overtime rather than the initial acceptance.

CPAP acceptance reflects the initial willingness for treatment while CPAP adherence reflects long-term compliance and continued management. Some dispute that CPAP acceptance and adherence differs in a meaningful way between age groups, however, evidence suggests both ways. One study demonstrated that age was not a predictor of such compliance factors (28). Some have found a decrease of CPAP use in elderly OSA (29), while others have found an increased rate (30,31). Regardless, in order to prevent fall off between initial acceptance and long-term adherence, it is important to understand that a fall off does exist. Nowadays, every sleep center understands these issues and tries their best to enhance CPAP adherence by implementing CPAP education strategies. The identification of actual predictors of CPAP adherence in real-world practice is essential since it helps enhance the management of OSA patients with more individualized management. Therefore, the objective of this study was to explore the factors influencing the adherence of CPAP in the elderly with OSA beyond the previously defined. We present this article in accordance with the STROBE reporting checklist (available at https://jtd.amegroups.com/article/view/10.21037/jtd-23-8/rc).


Methods

The retrospective observational study was conducted from OSA patients’ computerized medical records at Sleep Disorders Center, Center of Medical Excellence, Chiang Mai University Hospital, Chiang Mai, Thailand between 2018 and 2020. We reviewed the medical records of 1,070 patients who had overnight polysomnography (PSG). Inclusion Criteria were (I) the elderly aged 60 years old or more with confirmed diagnosis of OSA by overnight PSG at Sleep Disorders Center, Center of Medical Excellence, Chiang Mai University Hospital, Chiang Mai, Thailand during the study period; and (II) the elderly who were prescribed positive airway pressure (PAP) to use at home for a minimum of 1 month and up to 3 months. Exclusion criteria were the elderly with the normalize AHI (less than 5 events/hour), repeated studies included full-night PAP titration, or no evidence of sleep-disordered breathing (SDB) diagnosis. Thus, 336 elderly patients diagnosed with OSA met the indication for CPAP treatment eligibility for participation in the study. After receiving a CPAP prescription, we routinely monitored the patient for CPAP adherence criteria and kept a CPAP compliance record for at least one-year long.

The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The study was approved by the Ethics Committee of the Faculty of Medicine, Chiang Mai University, Thailand (Study code: MED-2564-08263, Date of approval: 14th October 2021), and individual consent for this retrospective analysis was waived.

Assessment of baseline demographic and clinical characteristics

We reviewed the medical history and physical examination including age, BMI, gender, neck circumference, and comorbidities (hypertension, DM, dyslipidemia, coronary artery disease, dilated cardiomyopathy, stroke, asthma, chronic obstructive pulmonary disease (COPD), chronic rhinitis, dementia, depression, and thyroid disease). Sleep history signs and symptoms including snoring, morning headache, witness apnea, recurrent awakening, nocturia, and EDS were also recorded. Daytime sleepiness was evaluated by the Epworth sleepiness scale (ESS), before overnight PSG. The ESS scores of 11–24 is considered to be abnormal and indicative of EDS (32,33).

Assessment of physical examination

A physical examination of the respiratory, cardiovascular, and nervous systems was performed routinely before the overnight PSG to screen and indicate an increased risk for OSA. We reviewed the physical examination data including Friedmann tongue position or modified Mallampati score, tonsil size, the present of long uvula, micrognathia and retrognathia or any craniofacial abnormality, and thyromental distance.

Overnight PSG

Routine PSG was performed in all subjects who met criteria for suspected OSA. PSG montage included monitoring of the electroencephalogram (EEG), electrooculogram (EOG), electromyogram (EMG), heart rate by 2-lead electrocardiogram (EKG), snoring intensity, leg movement, chest and abdominal movements (inductance plethysmography bands), nasal airflow (nasal cannula), mouth airflow (thermistor), oxygen saturation (pulse oximetry) and body position. Based on standard criteria, sleep stages were scored in 30-second sequential epochs based on EEG, EOG, and EMG, including non-rapid eye movement (NREM) and rapid eye movement (REM) sleep. According to the American Academy of Sleep Medicine (AASM) established recommendations, apnea was defined by a clear decrease (>90%) from baseline in the amplitude of the nasal pressure or thermistor signal lasting ≥10 seconds and was categorized as obstructive, mixed, or central apnea (34). Hypopnea was identified as a drop in airflow of more than 50% for at least 10 seconds or a moderate drop in airflow for at least 10 seconds from baseline in the amplitude of the nasal pressure or thermistor signal, or if there was a clear amplitude reduction of the nasal pressure signal ≥10 sec that did not reach the above criterion but associated with arousals or oxygen desaturation for 3% or more. AHI was classified as mild, moderate, and severe (AHI ranged from 5.0 to 15.0 events/hour, 15.1 to 30.0 events/hour, and more than 30 events/hour, respectively) (35). On the other hand, The AASM practice guideline in 1997, split night PSG protocol is allowed only when the AHI ≥40 events/hour for a minimum 2 hours of diagnosis time of PSG (36), however nowadays clinical judgment of using AHI >20 events/hour is a more liberal and reasonable criteria, and has gained more acceptance (37-39). The split night PSG protocol has been implemented in which the patient with suspected moderate or severe sleep apnea undergoes the diagnostic and therapeutic (PAP therapeutic) in one night.

CPAP acceptances

The following assessment criteria were used to determine the patient’s CPAP acceptance for this study: (I) accepts to use a CPAP during the PAP titration portion of the split-night PSG study. (II) Willingness to use the CPAP for treatment of OSA, once the patient acknowledges the sleep study result from a sleep specialist.

CPAP adherence and follow-up

At the initial visit after PSG, CPAP was prescribed by a sleep specialist to the patients indicating OSA. Since the pattern of adherence evidence can be discovered within the recent month of CPAP treatment, it showed that patients have already generated perceptions about the seriousness of OSA and the benefits of treatment, and these perceptions influence adherence. Thus, several educational and intensive support strategies have been proposed in this visit to the patients to recognize OSA as a major health issue and CPAP is the first line of treatment. Before initiating CPAP therapy, patients were given a chance to discuss their opinions regarding the diagnosis and the potential value of treatment. A short instruction session on how to use a CPAP device was also given to patients and their partners in the initial visit by a sleep technician and a trained nurse. Patients were also reminded in every follow-up visit. This included a practical learning demonstration of how to put on the CPAP mask, as well as turn on the CPAP machine and providing information on CPAP machine care and maintenance (changes of mask, tubes, and humidifier).

Once CPAP had been started, medical appointment was scheduled for all patients at Sleep Disorders Center outpatient unit every 3 months. Subjects brought their electronic record data card or CPAP device to each follow-up. Adherence to CPAP was always objectively assessed by reading the data recording card of CPAP devices from the last follow-up to current follow-up. Non-adherence is defined as using CPAP for less than an average of 4 hours each night or less than 70 percent of nights (i.e., less than five nights a week). Good adherence was defined as CPAP usage for at least 4 hours/night on at least 70% of nights. Only the data from the patients final follow-ups was presented in this study, Finally, CPAP adherence was analyzed at the one-year follow-up appointment. During these appointments, patients were encouraged to use the device while any problems with CPAP uses were addressed. The ESS was obtained as well as other clinical information regarding CPAP compliance. Furthermore, patients were assessed to determine any technical issues or negative effects they experienced while using their CPAP machines. Medications, if necessary, were prescribed to enhance the undesirable side effects of CPAP use (i.e., topical skin cream for any facial-interface problems, nasal decongestants for nose blockage, intranasal steroid for patients with persistent rhinitis).

In this study, factors which impair CPAP adherence were stratified into 2 categories: personal life problems and health-related problems. Personal life problems included the personal life issues and adverse attitudes towards treatment refer to issues relating to one of the following criteria: (I) negative attitudes about using CPAP, anxiety to use the device and difficulty falling asleep with it; (II) inconvenience in regular use as a result of life style patterns such as frequent travel or inappropriate sleep environments like public or working areas, odd work schedule, and from family issues like partner complaint; (III) inadequate CPAP comprehension which leads to a patient having an aversion to using CPAP equipment or incorrectly using the CPAP machine resulting in reduced effectiveness, ultimately resulting in decreased or stopped use; (IV) shift working or having an irregular sleep pattern due to work; (V) being unable to use the CPAP machine without a caregiver; (VI) removing the mask or having it come off through the night.

Health-related problems mean problems from other medical condition in one of the following criteria: (I) nasal congestion, runny nose, dry mouth, or nasal bleeding (II) abdominal distension or a sensation of bloating; and (III) medical conditions that precludes him or her from using CPAP (sleep specialist declare).

Statistical analysis

The distribution of continuous variables including age, BMI, ESS, minimum oxygen saturation, AHI and CPAP pressure was assessed by the Kolmogorov-Sminov test. The normally distributed variables were presented as mean ± standard deviation (SD). The non-normally distributed variables were presented as median and interquartile range (IQR). Categorical variables were expressed as absolute numbers and percentages. Independent sample t-tests and the Mann-Whitney U test were used to compare differences between groups for parametric and non-parametric data, respectively. Fisher’s exact test was used to compare the categorical data between groups. Multivariable risk regression analyses were performed to evaluate the independent factors associated with CPAP non-acceptance and CPAP non-adherence. The results were presented as adjusted risk ratio (RR) together with 95% confidence interval (CI). Statistical significance was set at a P value <0.05. All statistical analyses were performed using STATA version 16 (StataCorp, College Station, TX, USA).


Results

Of 1,070 patients who underwent PSG, 311 were excluded based on the following reasons: (I) AHI less than 5 events/hour; (II) repeated studies showing full night PAP titration PSG; (III) non-diagnosed with SDB; or (IV) missing informative data. The cohort was comprised of 759 patients diagnosed with OSA and requiring CPAP, a total of 336 elderly were enrolled in the study. One hundred and fifteen (34.2%) and 221 (65.8%) were classified as non-acceptance and acceptance, respectively (Figure 1).

Figure 1 Study flow chart. AHI, apnea hypopnea index; OSA, obstructive sleep apnea; PSG, polysomnography; CPAP, continuous positive airway pressure; PAP, positive airway pressure; SBD, sleep-related breathing disorders; PLM, periodic limb movements.

The average age was 70.7±7.9 and 69.2±7.9 years in non-acceptance group and acceptance group, respectively. There were no statistical or clinical differences observed between non-acceptance and acceptance group. The baseline demographics and clinical characteristics data were summarized in Table 1.

Table 1

Baseline demographic, sleep history, physical exam and PSG results of CPAP acceptance and non-acceptance in elderly OSA patients

Characteristics Non-acceptance (N=115) Acceptance (N=221) P value
Age (years) 70.7±7.9 69.2±7.9 0.133
BMI (kg/m2) 26.9±5.6 26.9±4.7 0.913
Neck circumference (inch) 15.4±1.7 15.2±1.6 0.252
Male sex 67 (58.3) 128 (57.9) 1
Number of comorbidities, median (IQR) 2 (1.0, 2.0) 2 (1.0, 3.0) 0.388
EDS define by ESS 73 (64.0) 137 (61.9) 0.812
Snoring 91 (79.8) 180 (81.5) 0.77
Morning headache 20 (17.5) 55 (24.9) 0.131
Witnessed apnea 30 (26.3) 54 (24.4) 0.79
Disrupted sleep and Recurrent awakening 20 (17.5) 29 (13.1) 0.328
Nocturia 62 (54.4) 137 (61.2) 0.197
Modified Friedmann Tongue position/Mallampati score 0.19
   Grade I 3 (2.7) 5 (2.3)
   Grade IIa 7 (6.3) 25 (11.5)
   Grade IIb 21 (18.8) 45 (20.6)
   Grade III 77 (68.8) 129 (59.2)
   Grade IV 3 (2.7) 14 (6.4)
Tonsil size 0.058
   Grade 0 1 (0.9) 0 (71.3)
   Grade I 90 (81.1) 155 (71.1)
   Grade II 13 (11.7) 38 (17.4)
   Grade III 4 (3.6) 21 (9.6)
   Grade IV 3 (2.7) 4 (1.8)
Micrognathia 61 (54.5) 127 (58.8) 0.481
Retrognathia 18 (16.1) 30 (13.9) 0.623
Long uvula 1 (0.9) 4 (1.8) 0.664
Thyromental distance (inch), median (IQR) 3 (2.5, 4.0) 3 (2.5, 5.8) 0.175
AHI total, median (IQR) 71.8 (53.3, 86.6) 65.5 (43.8, 83.0) 0.045
AHI REM, median (IQR) 0.0 (0.0, 27.5) 0.0 (0.0, 41.1) 0.552
AHI non-REM, median (IQR) 72.6 (50.8, 87.8) 66.4 (44.3, 83.4) 0.045

Data are presented as mean ± SD or n (%), otherwise was stated. PSG, polysomnography; BMI, body mass index; CPAP, continuous positive airway pressure; EDS, excessive daytime sleepiness; ESS, Epworth Sleepiness Scale; OSA, obstructive sleep apnea; AHI, Apnea Hypopnea Index; REM, rapid eye movement.

CPAP adherence

Of the total 221 elderly patients that accepted CPAP, only 166 patients continued through to the one-year follow-up, including 27 (16.3%) non-adherence and 139 (83.7%) adherences. Fifty five of 221 (24.8%) patients lost follow up. There was no significant difference in age, BMI, neck circumference, number of comorbidities, ESS score, EDS, snoring, morning headache and witness apnea, between the non-adherence and adherence groups (Table 2).

Table 2

Baseline demographic, sleep history, physical exam and PSG results of adherence and non-adherence in elderly OSA patients

Characteristics Non-adherence (N=27) Adherence (N=139) P value
Age (years) 70.9±8.9 68.3±6.9 0.087
BMI (kg/m2) 26.8±3.9 27.3±4.5 0.625
Neck circumference (inch) 15.1±1.6 15.2±1.6 0.649
Male sex 11 (40.7) 81 (58.2) 0.138
Number of comorbidities, median (IQR) 2 (1.0, 3.0) 2 (1.0, 3.0) 0.892
ESS score 9.07±4.70 8.23±4.69 0.394
EDS 17 (62.96) 93 (66.91) 0.824
Snoring 21 (77.78) 101 (72.66) 0.643
Morning headache 8 (29.63) 33 (23.74) 0.626
Witness Apnea 5 (18.52) 34 (24.46) 0.624
Recurrent awakening 5 (18.52) 19 (13.67) 0.551
Nocturia 12 (44.44) 81 (58.27) 0.208
Friedmann Tongue position/Mallampati score 0.452
   Grade I 0 (0.0) 2 (1.4)
   Grade IIa 2 (7.4) 20 (14.4)
   Grade IIb 9 (33.3) 25 (17.9)
   Grade III 15 (55.6) 83 (59.7)
   Grade IV 1 (3.7) 9 (6.5)
Tonsil size 0.371
   Grade 0 17 (62.9) 93 (66.9)
   Grade I 4 (14.8) 29 (20.8)
   Grade II 5 (18.5) 15 (10.8)
   Grade III 1 (3.7) 2 (1.4)
   Grade IV 0 (0.0) 0 (0.0)
Micrognathia 16 (59.3) 78 (56.1) 0.834
Retrognathia 3 (11.1) 23 (16.6) 0.576
Long uvula 0 (0.0) 2 (1.44) 1
Minimum O2 saturation 81.9±4.6 81.3±8.6 0.697
Total sleep time with O2sat <90%, median (IQR) 5.1 (0.9–24.7) 5 (0.4–30.8) 0.796
CPAP pressure (cmH2O) 7.9±3.0 8.4±2.9 0.488
AHI total, median (IQR) 60.6 (42.5, 83.3) 68.3 (44.6, 82.8) 0.413
AHI REM, median (IQR) 0.0 (0.0, 42.4) 0.0 (0.0, 35.6) 0.5
AHI non-REM, median (IQR) 62.2 (43.5, 85.4) 69.3 (45.7, 82.8) 0.603

Data are presented as mean ± SD or n (%), otherwise was stated. BMI, body mass index; CPAP, continuous positive airway pressure; EDS, excessive daytime sleepiness; ESS, Epworth Sleepiness Scale; OSA, obstructive sleep apnea; PSG, polysomnography; AHI, Apnea Hypopnea Index; REM, rapid eye movement.

Factors associated with CPAP acceptance and CPAP adherence

From multivariable risk regression analysis, all of variables including age, sex, snoring sleep history, morning headache, comorbidities, ESS score, BMI, neck circumference, and AHI were not significantly associated with CPAP non- acceptance (Table 3). Elderly patients diagnosed with OSA with personal life problems or adverse attitudes towards CPAP had lower adherence to CPAP use [adjusted RR =4.59 (95% CI: 1.79, 11.78), P=0.002]. Female was also associated with low CPAP adherence with adjusted RR =3.10 (95% CI: 1.07, 9.01), P=0.037. Moreover, age, and comorbidities were not shown to affect adherence in our study. More data are shown in Table 4. The factors associated with CPAP adherence data were demonstrated in the Table 5.

Table 3

Summary of the factors associated with CPAP non-acceptance in elderly with OSA

Factors Adjusted risk ratio (95% CI) P value
Age group (years)
   60–69 Reference
   70–79 1.05 (0.75, 1.46) 0.784
   ≥80 1.30 (0.88, 1.94) 0.192
Sex
   Male Reference
   Female 0.92 (0.65, 1.29) 0.623
Snoring
   Non-snoring Reference
   Snoring 1.03 (0.72, 1.46) 0.889
Morning headache
   Has morning headache Reference
   No morning headache 0.98 (0.70, 1.39) 0.945
Diabetes mellitus
   No Reference
   Yes 0.81 (0.56, 1.18) 0.273
Cardiovascular diseases
   No Reference
   Yes 0.88 (0.65, 1.19) 0.424
Respiratory diseases
   No Reference
   Yes 1.01 (0.76, 1.35) 0.937
Neurological disorders
   No Reference
   Yes 0.58 (0.19, 1.84) 0.358
ESS
   <10 Reference
   ≥10 1.05 (0.79, 1.40) 0.727
BMI (kg/m2)
   <30 Reference
   ≥30 1.15 (0.78, 1.69) 0.476
Neck circumference (inch) 0.98 (0.87, 1.10) 0.705
AHI total 0.99 (0.96, 1.04) 0.894
AHI REM 0.99 (0.98, 1.00) 0.451
AHI non-REM 1.00 (0.97, 1.04) 0.731

OSA, obstructive sleep apnea; BMI, body mass index; CPAP, continuous positive airway pressure; ESS, Epworth Sleepiness Scale; AHI, Apnea Hypopnea Index; REM, rapid eye movement.

Table 4

Summary of the factors associated with low CPAP adherence in elderly with OSA

Factors Adjusted risk ratio (95% CI) P value
Age group (years)
   60–69 Reference
   70–79 1.19 (0.42, 3.44) 0.740
   ≥80 2.56 (0.83, 7.92) 0.102
Sex
   Male Reference
   Female 3.10 (1.07, 9.01) 0.037
Snoring
   Non-snoring Reference
   Snoring 1.93 (0.61, 6.15) 0.266
Morning headache
   Has morning headache Reference
   No morning headache 0.89 (0.32, 2.48) 0.821
Diabetes mellitus
   No Reference
   Yes 0.82 (0.23, 2.98) 0.764
Cardiovascular diseases
   No Reference
   Yes 0.53 (0.19, 1.41) 0.201
Respiratory diseases
   No Reference
   Yes 2.44 (0.87, 6.83) 0.089
Neurological disorders
   No Reference
   Yes 0.23 (0.02, 3.00) 0.260
ESS
   <10 Reference
   ≥10 1.31 (0.51, 3.34) 0.572
BMI (kg/m2)
   <30 Reference
   ≥30 0.93 (0.27, 3.12) 0.901
Neck circumference (inch) 1.23 (0.86, 1.76) 0.248
Personal life issues and adverse attitudes
   No personal/attitude problems Reference
   Has personal/attitude problems 4.59 (1.79, 11.78) 0.002
Health related problems
   No health-related problems Reference
   Has health related problems 2.33 (0.79, 6.86) 0.126
AHI total 0.99 (0.84, 1.18) 0.985
AHI REM 0.99 (0.98, 1.01) 0.491
AHI non-REM 0.99 (0.83, 1.18) 0.905

OSA, obstructive sleep apnea; BMI, body mass index; CPAP, continuous positive airway pressure; ESS, Epworth Sleepiness Scale; AHI, Apnea Hypopnea Index; REM, rapid eye movement.

Table 5

Illustrate the problems relevant with CPAP use

Category Problems Number of subjects
Personal life/attitude issues (I) Anxiety to use a CPAP device without any explainable cause or difficulty falling to sleep with CPAP 25
(II) Inconvenience in regularly use as a result of life style patten prohibit CPAP use such as frequent travel or inappropriate sleep environments such as public or working areas and living as a family cause partner complaint 5
(III) Inadequate CPAP comprehension leads to inability to use the equipment and correctly wear an Interface (i.e., mask) 4
(IV) Shift working cause irregular sleep pattern who found difficulty in CPAP use 1
(V) Need a caregiver for proper initiating the CPAP mask fitting or CPAP operation 1
(VI) Waking up in the middle of the night and unable to continue wearing the device without explainable cause 8
Health-related problem (I) Congestion, runny nose, dry mouth, or nosebleeds 15
(II) Abdominal distension or a sensation of bloating 1
(III) The subject has a medical issue that precludes him or her from using CPAP (recent ophthalmologic surgery) 1

CPAP, continuous positive airway pressure.


Discussion

CPAP is a very effective treatment for OSA, as aforementioned, but is limited by non-adherence and compliance issues (13,14,40). However, it is important to note that studies among CPAP use in elderly OSA are still limited by sample size and results. Previous studies on an association between CPAP adherence and age showed that compliance varied dramatically by age and sex, ranging from 51.3% in 18- to 30-year-old women to 80.6% in 71- to 80-year-old men. Use steadily increased among older patients, taking more than a week to maximize usage, with a much higher success rate in use over time (41). In our study, the overall rate of CPAP acceptance in elderly OSA patients was 34.2%, which is close to the 31.5% CPAP acceptance rate determined in the previous study (42). There were no significant factors correlated with CPAP acceptance in our patients except the marginal difference in baseline AHI between CPAP acceptance and non-acceptance. External factors such as healthcare coverage and the expense of CPAP equipment may contribute to CPAP acceptance rates as well. This small difference might not be enough to make a strong conclusion. After correcting the barrier from health-related problems that interfere with CPAP use in each follow up visit by sleep specialist, our study illustrates that the low CPAP adherence in elderly OSA patients in one-year follow-up was only significantly correlated with the personal life or attitude of the subject, contrast to the previous study which demonstrated that high age was an independent risk factor for non-compliance due to a variety of problems in the nose or pharynx (29). For this reason we sought to explore the factors that influence CPAP adherence and separate them from acceptance factors to enhance CPAP effectiveness and our capability to help with adherence. This distinctive information will benefit CPAP successfulness in elderly OSA patients by informing the creation of engagement techniques for CPAP use, or at least by removing a possible barrier to use. We also found that female was associated with low CPAP adherence. Our results were supported from the previous study indicating that female are the robust factors that associated with low CPAP adherence in subject with OSA (43,44). However, the reason for low CPAP adherence in female in this study is not clear. Because, other factors including income, socioeconomic status, number of family members, lack of social support were not available in our study. These factors could affect the CPAP adherence.

The strengths of this study were: firstly, we used objective adherence measurement rather than subjective adherence monitoring to ensure that patients’ adherence rates were accurate. Secondly, all of the eligible patients got the same CPAP education programs from the same CPAP education staffs. Thirdly, the benefit of CPAP use was emphasized and repetitively encouraged by a team consisting of the same sleep specialist physician, certified sleep technologist, and nurse from the beginning to end of study. Educating patients about CPAP requires a considerable amount of time and effort, and exploring the factors related to personal life or attitudes were even tougher. It might need both science and art in approaching. Despite the usefulness of CPAP knowledge, the patient and family may need more dialogue and conversation about their life beyond just the OSA discussion. By keeping a consistent patient-health care relationship, we believe that the barrier to CPAP use could be overcome.

It is, however, important to note there are some limitations in our study that require consideration. Firstly, subjects were selected from one single center and the number of subjects in CPAP non-adherence group is too small (n=27) which restricts the generalizability of the study findings. Secondly, every patient got intensive education about OSA and CPAP and behavioral interventions which might have positive effects on adherence, leading to the conclusion that improving OSA elderly patient adherence to CPAP therapy necessarily requires a multi-layered approach combining technological, behavioral, and adverse-effect interventions. Finally, according to a retrospective cohort study, we did not collect qualitative or survey data which would have additionally allowed us to assess the reasons for patients who did not accept CPAP.


Conclusions

In our largest cohort to date, elderly OSA patients treated with CPAP over long-term follow-ups demonstrated that adherence rates were associated with personal life issues and adverse attitudes towards treatment as well as health problems. Female was also associated with low CPAP adherence. Therefore, in the elderly with OSA, the indication and treatment of CPAP should be customized individually, and if prescribed, regular monitoring to address noncompliance and tolerance should be considered. Further prospective studies to identify the benefit outcome of individual elderly who met the indication for CPAP and characteristics of CPAP use over one year at different time points should be considered for correcting adherence problems prior to drawing any final conclusion.


Acknowledgments

The authors would like to thank all subjects who participated in this study. The authors also would like to acknowledge the contribution of the staff of the Sleep Disorders Center, Center of Medical Excellence, Chiang Mai University Hospital, Chiang Mai, Thailand.

Funding: This research was granted by the Center of Medical Excellence, Chiang Mai University, Chiang Mai, Thailand.


Footnote

Provenance and Peer Review: This article was a standard submission to the series “Sleep Section” published in the Journal of Thoracic Disease. The article has undergone external peer review.

Reporting Checklist: The authors have completed the STROBE reporting checklist. Available at https://jtd.amegroups.com/article/view/10.21037/jtd-23-8/rc

Data Sharing Statement: Available at https://jtd.amegroups.com/article/view/10.21037/jtd-23-8/dss

Peer Review File: Available at https://jtd.amegroups.com/article/view/10.21037/jtd-23-8/prf

Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at https://jtd.amegroups.com/article/view/10.21037/jtd-23-8/coif). The series “Sleep Section” was commissioned by the editorial office without any funding or sponsorship. The authors have no other conflicts of interest to declare.

Ethical Statement: The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. The study was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The study was approved by the Ethics Committee of the Faculty of Medicine, Chiang Mai University, Thailand (Study code: MED-2564-08263, Date of approval: 14th October 2021), and individual consent for this retrospective analysis was waived.

Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0/.


References

  1. Jordan AS, McSharry DG, Malhotra A. Adult obstructive sleep apnoea. Lancet 2014;383:736-47. [Crossref] [PubMed]
  2. American Sleep Disorders Association, Diagnostic Classification Steering Committee. International classification of sleep disorders: diagnostic and coding manual, ICSD-R. American Academy of Sleep Medicine, Westchester, IL; 2005.
  3. Senaratna CV, Perret JL, Lodge CJ, et al. Prevalence of obstructive sleep apnea in the general population: A systematic review. Sleep Med Rev 2017;34:70-81. [Crossref] [PubMed]
  4. Cairns A, Poulos G, Bogan R. Sex differences in sleep apnea predictors and outcomes from home sleep apnea testing. Nat Sci Sleep 2016;8:197-205. [Crossref] [PubMed]
  5. Kawada T, Otsuka T, Nakamura T, et al. Relationship between sleep-disordered breathing and metabolic syndrome after adjustment with cardiovascular risk factors. Diabetes Metab Syndr 2016;10:92-5. [Crossref] [PubMed]
  6. Sofi F, Cesari F, Casini A, et al. Insomnia and risk of cardiovascular disease: a meta-analysis. Eur J Prev Cardiol 2014;21:57-64. [Crossref] [PubMed]
  7. Kendzerska T, Gershon AS, Hawker G, et al. Obstructive sleep apnea and risk of cardiovascular events and all-cause mortality: a decade-long historical cohort study. PLoS Med 2014;11:e1001599. [Crossref] [PubMed]
  8. Dong JY, Zhang YH, Qin LQ. Obstructive sleep apnea and cardiovascular risk: meta-analysis of prospective cohort studies. Atherosclerosis 2013;229:489-95. [Crossref] [PubMed]
  9. Turgut Celen Y, Peker Y. Cardiovascular consequences of sleep apnea: II-Cardiovascular mechanisms. Anadolu Kardiyol Derg 2010;10:168-75. [Crossref] [PubMed]
  10. Engleman HM, Douglas NJ. Sleep. 4: Sleepiness, cognitive function, and quality of life in obstructive sleep apnoea/hypopnoea syndrome. Thorax 2004;59:618-22. [Crossref] [PubMed]
  11. Ellen RL, Marshall SC, Palayew M, et al. Systematic review of motor vehicle crash risk in persons with sleep apnea. J Clin Sleep Med 2006;2:193-200. [PubMed]
  12. Howard ME, Desai AV, Grunstein RR, et al. Sleepiness, sleep-disordered breathing, and accident risk factors in commercial vehicle drivers. Am J Respir Crit Care Med 2004;170:1014-21. [Crossref] [PubMed]
  13. Cao MT, Sternbach JM, Guilleminault C. Continuous positive airway pressure therapy in obstuctive sleep apnea: benefits and alternatives. Expert Rev Respir Med 2017;11:259-72. [Crossref] [PubMed]
  14. Batool-Anwar S, Goodwin JL, Kushida CA, et al. Impact of continuous positive airway pressure (CPAP) on quality of life in patients with obstructive sleep apnea (OSA). J Sleep Res 2016;25:731-8. [Crossref] [PubMed]
  15. Martínez-García MA, Soler-Cataluña JJ, Ejarque-Martínez L, et al. Continuous positive airway pressure treatment reduces mortality in patients with ischemic stroke and obstructive sleep apnea: a 5-year follow-up study. Am J Respir Crit Care Med 2009;180:36-41. [Crossref] [PubMed]
  16. Milleron O, Pillière R, Foucher A, et al. Benefits of obstructive sleep apnoea treatment in coronary artery disease: a long-term follow-up study. Eur Heart J 2004;25:728-34. [Crossref] [PubMed]
  17. Marin JM, Carrizo SJ, Vicente E, et al. Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study. Lancet 2005;365:1046-53. [Crossref] [PubMed]
  18. Kribbs NB, Pack AI, Kline LR, et al. Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am Rev Respir Dis 1993;147:887-95. [Crossref] [PubMed]
  19. Reeves-Hoche MK, Meck R, Zwillich CW. Nasal CPAP: an objective evaluation of patient compliance. Am J Respir Crit Care Med 1994;149:149-54. [Crossref] [PubMed]
  20. Kohler M, Smith D, Tippett V, et al. Predictors of long-term compliance with continuous positive airway pressure. Thorax 2010;65:829-32. [Crossref] [PubMed]
  21. Weaver TE, Sawyer AM. Adherence to continuous positive airway pressure treatment for obstructive sleep apnoea: implications for future interventions. Indian J Med Res 2010;131:245-58. [PubMed]
  22. Meslier N, Lebrun T, Grillier-Lanoir V, et al. A French survey of 3,225 patients treated with CPAP for obstructive sleep apnoea: benefits, tolerance, compliance and quality of life. Eur Respir J 1998;12:185-92. [Crossref] [PubMed]
  23. Wells RD, Freedland KE, Carney RM, et al. Adherence, reports of benefits, and depression among patients treated with continuous positive airway pressure. Psychosom Med 2007;69:449-54. [Crossref] [PubMed]
  24. Hoffstein V, Viner S, Mateika S, et al. Treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Patient compliance, perception of benefits, and side effects. Am Rev Respir Dis 1992;145:841-5. [Crossref] [PubMed]
  25. Broström A, Fridlund B, Hedberg B, et al. Communication between patients with obstructive sleep apnoea syndrome and healthcare personnel during the initial visit to a continuous positive airway pressure clinic. J Clin Nurs 2017;26:568-77. [Crossref] [PubMed]
  26. Ulander M, Johansson MS, Ewaldh AE, et al. Side effects to continuous positive airway pressure treatment for obstructive sleep apnoea: changes over time and association to adherence. Sleep Breath 2014;18:799-807. [Crossref] [PubMed]
  27. Hwang D. Monitoring Progress and Adherence with Positive Airway Pressure Therapy for Obstructive Sleep Apnea: The Roles of Telemedicine and Mobile Health Applications. Sleep Med Clin 2016;11:161-71. [Crossref] [PubMed]
  28. Weaver TE, Chasens ER. Continuous positive airway pressure treatment for sleep apnea in older adults. Sleep Med Rev 2007;11:99-111. [Crossref] [PubMed]
  29. Janson C, Nöges E, Svedberg-Randt S, et al. What characterizes patients who are unable to tolerate continuous positive airway pressure (CPAP) treatment? Respir Med 2000;94:145-9. [Crossref] [PubMed]
  30. Poulet C, Veale D, Arnol N, et al. Psychological variables as predictors of adherence to treatment by continuous positive airway pressure. Sleep Med 2009;10:993-9. [Crossref] [PubMed]
  31. Galetke W, Anduleit N, Richter K, et al. Comparison of automatic and continuous positive airway pressure in a night-by-night analysis: a randomized, crossover study. Respiration 2008;75:163-9. [Crossref] [PubMed]
  32. Johns M, Hocking B. Daytime sleepiness and sleep habits of Australian workers. Sleep 1997;20:844-9. [Crossref] [PubMed]
  33. Johns MW. Daytime Sleepiness, snoring, and obstructive sleep apnea: The Epworth Sleepiness Scale. Chest 1993;103:30-6. [Crossref] [PubMed]
  34. Berry RB, Budhiraja R, Gottlieb DJ, et al. Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med 2012;8:597-619. [Crossref] [PubMed]
  35. Iber C, Ancoli-Israel S, Quan SF. The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications. American Academy of Sleep Medicine, New York; 2007.
  36. Chesson AL Jr, Ferber RA, Fry JM, et al. The indications for polysomnography and related procedures. Sleep 1997;20:423-87. [Crossref] [PubMed]
  37. Sanders MH, Black J, Costantino JP, et al. Diagnosis of sleep-disordered breathing by half-night polysomnography. Am Rev Respir Dis 1991;144:1256-61. [Crossref] [PubMed]
  38. Yamashiro Y, Kryger MH. CPAP titration for sleep apnea using a split-night protocol. Chest 1995;107:62-6. [Crossref] [PubMed]
  39. Iber C, O'Brien C, Schluter J, et al. Single night studies in obstructive sleep apnea. Sleep 1991;14:383-5. [PubMed]
  40. Drager LF, Togeiro SM, Polotsky VY, et al. Obstructive sleep apnea: a cardiometabolic risk in obesity and the metabolic syndrome. J Am Coll Cardiol 2013;62:569-76. [Crossref] [PubMed]
  41. Patel SR, Bakker JP, Stitt CJ, et al. Age and Sex Disparities in Adherence to CPAP. Chest 2021;159:382-9. [Crossref] [PubMed]
  42. Yang MC, Lin CY, Lan CC, et al. Factors affecting CPAP acceptance in elderly patients with obstructive sleep apnea in Taiwan. Respir Care 2013;58:1504-13. [Crossref] [PubMed]
  43. Joo MJ, Herdegen JJ. Sleep apnea in an urban public hospital: assessment of severity and treatment adherence. J Clin Sleep Med 2007;3:285-8. [Crossref] [PubMed]
  44. Woehrle H, Graml A, Weinreich G. Age- and gender-dependent adherence with continuous positive airway pressure therapy. Sleep Med 2011;12:1034-6. [Crossref] [PubMed]
Cite this article as: Tiyapun N, Sunkonkit K, Chaiwong W, Worasuthaneewan R, Theerakittikul T. Factors influencing continuous positive airway pressure adherence in elderly with obstructive sleep apnea. J Thorac Dis 2023;15(6):3488-3500. doi: 10.21037/jtd-23-8

Download Citation