Pulse rate trends in obstructive sleep apnea: a reliable tool to predict long term response to CPAP?
Letter to the Editor

Pulse rate trends in obstructive sleep apnea: a reliable tool to predict long term response to CPAP?

Javier Navarro-Esteva1, Antonio Ravelo-García2, Ibrahim Véliz-Flores1, Guillermo Pérez-Mendoza1, Antonio M. Esquinas3

1Department of Pulmonary Medicine, Hospital Universitario Gran Canaria “Dr. Negrin”, Las Palmas, Spain; 2Institute for Technological Development and Innovation in Communications (IDeTIC), Universidad de Las Palmas de Gran Canaria, Las Palmas, Spain; 3Intensive Care Unit, Hospital Morales Meseguer, Murcia, Spain

Correspondence to: Javier Navarro-Esteva, MD. Department of Pulmonary Medicine, Hospital Universitario Gran Canaria “Dr. Negrin”, Las Palmas, Spain. Email: jnavest@gobiernodecanarias.org.

Submitted Aug 08, 2014. Accepted for publication Aug 08, 2014.

doi: 10.3978/j.issn.2072-1439.2014.08.35


To the editor,

A predictive model of long term response to CPAP could be a useful tool for the clinician. In this regard, previous studies considered that changes in heart rate variability (HRV) are a key variable to assess continuous positive airway pressure (CPAP) response (1,2). We read with interest the recent article by Pengo MF et al. (3) were authors hypothesized that baseline nocturnal pulse rate (PR) trends help predict long term response to CPAP. In this study, main findings were improvement in daytime sleepiness among obstructive sleep apnea (OSA) patients with baseline negative change in PR contrary to OSA patients with positive change in PR. Nonetheless, we consider that a few aspects of this study deserve reviewing.

First, the diagnostic modality was unattended pulse oximetry. So far, the published data on this method is difficult to compare because of differences in the parameters measured and differences in the reference standard. Some studies reported high specificity while others reported a high sensitivity. For screening purposes, both high sensitivity and high pretest likelihood of OSA are needed. Additionally, age, pulmonary function, and degree of obesity impact on nocturnal desaturation and also influence sensitivity and specificity. Therefore, for research purposes, diagnosis should be confirmed by polygraphy or polysomnography (4-6).

In Pengo MF et al. patients in the OSA group had lower mean saturation of hemoglobin (SpO2) than controls (92.7% vs. 95.4%). This difference makes the OSA group more likely to desaturate during sleep just by virtue of the oxyhemoglobin dissociation curve dynamics (5). Furthermore, some of the OSA patients may have suffered from other comorbidities such as obesity hypoventilation syndrome. This was more likely in the OSA group with positive change PR, where patients were more obese (122+/–26 kg) and had lower mean SpO2 (90.9%) compared to those with negative change PR (107+/–26 kg, and 93.2%, respectively).

Secondly, inclusion criteria required a ≥4% oxygen desaturation index (ODI) ≥15 or ODI ≥5 plus Epworth sleepiness score (ESS) >10. In the developed world, prevalence of daytime hypersomnolence is significantly higher than OSA (7), so subjects with mild OSA were probably overtreated with CPAP.

Third, pulse rate index (PRI) > or

In a previous study, Zamarrón C et al. found no significant nightly changes in PR trends among 111 OSA patients (8). In the article by Pengo MF et al., it is not clear how PR trend is defined and why it is considered a determinant variable. One wonders how such a trend makes a patient more or less prone to respond to CPAP. Moreover, different CPAP compliance among OSA groups makes both this hypothesis and ESS outcomes unreliable.

In a nutshell, HRV reflects the relationship between parasympathetic and sympathetic nervous system, and, when abnormal, it raises the risk to future cardiovascular problems. In regard to the work by Pengo MF et al., we think careful subject characterization and confirmed diagnosis is required, and we agree with the authors that more studies about PR and HRV analysis on assessing CPAP response are needed. Concomitantly, a more reliable pulse oximetry analysis might be used for doubtful OSA wherever access to polygraphy or polysomnography is limited (8-10).


Acknowledgements

Disclosure: The authors declare no conflict of interest.


References

  1. Kufoy E, Palma JA, Lopez J, et al. Changes in the heart rate variability in patients with obstructive sleep apnea and its response to acute CPAP treatment. PLoS One 2012;7:e33769. [PubMed]
  2. Kawano Y, Tamura A, Watanabe T, et al. Influence of the severity of obstructive sleep apnea on heart rate. J Cardiol 2010;56:27-34. [PubMed]
  3. Pengo MF, Drakatos P, Kosky C, et al. Nocturnal pulse rate and symptomatic response in patients with obstructive sleep apnoea treated with continuous positive airway pressure for one year. J Thorac Dis 2014;6:598-605. [PubMed]
  4. Rofail LM, Wong KK, Unger G, et al. Comparison between a single-channel nasal airflow device and oximetry for the diagnosis of obstructive sleep apnea. Sleep 2010;33:1106-14. [PubMed]
  5. Lévy P, Pépin JL, Deschaux-Blanc C, et al. Accuracy of oximetry for detection of respiratory disturbances in sleep apnea syndrome. Chest 1996;109:395-9. [PubMed]
  6. Mazière S, Pépin JL, Siyanko N, et al. Usefulness of oximetry for sleep apnea screening in frail hospitalized elderly. J Am Med Dir Assoc 2014;15:447.e9-14.
  7. Hayley AC, Williams LJ, Kennedy GA, et al. Prevalence of excessive daytime sleepiness in a sample of the Australian adult population. Sleep Med 2014;15:348-54. [PubMed]
  8. Zamarrón C, Hornero R, del Campo F, et al. Heart rate regularity analysis obtained from pulse oximetric recordings in the diagnosis of obstructive sleep apnea. Sleep Breath 2006;10:83-9. [PubMed]
  9. Heneghan C, Chua CP, Garvey JF, et al. A portable automated assessment tool for sleep apnea using a combined Holter-oximeter. Sleep 2008;31:1432-9. [PubMed]
  10. Roche F, Celle S, Pichot V, et al. Analysis of the interbeat interval increment to detect obstructive sleep apnoea/hypopnoea. Eur Respir J 2007;29:1206-11. [PubMed]
Cite this article as: Navarro-Esteva J, Ravelo-García A, Véliz-Flores I, Pérez-Mendoza G, Esquinas AM. Pulse rate trends in obstructive sleep apnea: a reliable tool to predict long term response to CPAP? J Thorac Dis 2014;6(9):E198-E199. doi: 10.3978/j.issn.2072-1439.2014.08.35

Download Citation